Setting the Meter
Setting the Weighting
PressWEIGHTINGtoselectAorC.
Weightingdeterminesthemeter’sfrequencyresponse
curve.
A-weightinghasA-curvefrequencycharacteristicsand
causesthemetertorespondmainlytofrequenciesranging
from500to10,000Hz.Thisisthehumanear’smostsensitive
range.SelectAtodeterminethenoiselevelofanarea.
C-weightinghasC-curve(at)frequencycharacteristicsand
causesthemetertorespondmainlytofrequenciesranging
from32to10,000Hz.SelectCtomeasuresoundlevelsof
musicalmaterial.
n Note: You can change the weighting setting only during
a continuous average or maximum measurement.
Setting the Response Time
PressRESPONSEtoselectFASTorSLOW.
WhensettoFAST,themeterupdatesthebargraphevery
0.2seconds.WhensettoSLOW,themeterupdatesthebar
graphevery0.5seconds.
n Note: You can change
the response setting
only during a continuous
average or maximum
measurement.